The CR200 is our lowest-cost data logger. Its input channel configuration and small size is optimal for measuring one or two sensors. When paired with an ENC200 enclosure and the small 16869 battery, the packaged CR200 has a deployment size of only 6 inches by 7 inches.
The CR200 is the base model in the CR200 datalogger series. Three related models, the CR206, CR211, and CR216, carry onboard, spread-spectrum radios, and the CR295 is specially equipped for use with the TX312 GOES transmitter.
-NOTE- | Note: Additional specifications are listed in the CR200-Series Specifications Sheet. |
A/D Converter | 12 bit |
Maximum Scan Rate | Once per second |
Single-Ended Analog Channels | 5 (individually configured) |
Analog Voltage Range | 0 to +2500 mV |
Measurement Resolution | 0.6 mV |
Excitation Channels | 2 (programmable for either +2.5 or +5 volts) |
Switched Battery Port | 1 |
Pulse Count Channels | 2 |
Control Ports | 2 |
Battery Voltage Range | 7 to 16 Vdc |
Communications | RS-232 |
Campbell Scientific’s SDM devices and multiplexers are not supported.
The CR200 cannot make differential measurements and is not compatible with thermocouples, our geographic position sensor, fuel moisture/temperature probe, and soil heat flux sensors. However, it can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. Our CS625 Reflectometer, 109 Thermistor, and CS15 Electric Current Sensor were specifically developed for our CR200-series dataloggers. Other compatible sensors include wind sets, tipping buckets, and barometers. For a complete list of compatible sensors, see the CR200-series brochure.
The CR200 can communicate with a PC via direct connect, NL100 Ethernet interface, MD485 multidrop modem, and digital cellular modems. Data can be viewed on the CD295 DataView II display or a PDA (PConnect or PConnectCE software required).
Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the #16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the #16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR200-based systems.
When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 Ahr or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.
Before March 2005, a CD was shipped with PakCom PC software and PakBus ActiveX (OCX). Effective, 3 March 2005, our DevConfig, PC200W, and Short Cut packages began to include support for the CR200 dataloggers. These programs are available for download from our website or are on our ResourceCD.
Default operating system loaded into the datalogger at the factory. Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.
Use of this file will update the datalogger compiler and CRBasic Editor support files.
Includes: ETo, WindVector, LoggerIdentify
Excludes: GOES Instructions, SDI12Sensor, SerialInput, MODBUS Instructions, SendData
Special operating system that supports ModBus communication and SDI-12 sensors . Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.
Use of this file will update the datalogger compiler and CRBasic Editor support files.
Note: Not to be used with the CR200X series.
Includes: MODBUS Instructions, SDI12Sensor, WindVector
Excludes: GOES Instructions, SerialInput, ETO, SendData, & LoggerIdentify
Special operating system that supports serial sensors, SDI-12 sensors, and sending data to another PakBus device. Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.
Use of this file will update the datalogger compiler and CRBasic Editor support files.
Includes: SerialInput, SendData, SDI12Sensor, WindVector
Excludes: GOES Instructions, ETo, MODBUS Instructions, LoggerIdentify
A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.
Supported Operating Systems:
Windows 11 or 10 (Both 32 and 64 bit)
Short Cut creates simple programs for our CR200-series, CR300-series, CR510, CR500, CR10(X), 21X, CR23X, CR6, CR800, CR1000(X), CR1000Xe, CR3000, CR5000, CR9000X and GRANITE dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.