| 利用できるサービス | |
|---|---|
| 修理 | 非対応 |
| キャリブレーション | 非対応 |
| フリーサポート | 非対応 |
The MCR1 is only compatible with our mixed-array data loggers and the DSP4 Heads Up Display. (See the Compatibility information.) In a single package, it includes both the CSM1 and a SC532(A). The MCR1 connects to an IBM-compatible computer via a 7026 cable (supplied). AC power and SMS software are required.
Please note that availability varies by country; please contact a Campbell Scientific office or representative to discuss your data storage requirements.
続きを読む
The MCR1 is only compatible with our mixed-array data loggers and the DSP4 Heads Up Display. (See the Compatibility information.) In a single package, it includes both the CSM1 and a SC532(A). The MCR1 connects to an IBM-compatible computer via a 7026 cable (supplied). AC power and SMS software are required.
Please note that availability varies by country; please contact a Campbell Scientific office or representative to discuss your data storage requirements.
| Memory Configuration | Fill-and-stop; data segregated into files by filemarks |
| Baud Rate | Data transfer is typically 9600 or 19,200 baud. Contact Campbell Scientific for information on using the module with Burst Mode. |
| Supply Voltage | 110 Vac to 7.5 Vdc adapter (factory installed) or 6 to 17 Vdc (with modification by user) |
| Interface Type | 25-pin, D-type sub-miniature socket, RS-232C DCE interface |
| RS-232 Output Levels | 5 V (minimum with 3000 Ω load) |
Current Drain @ 25°C |
|
| Quiescent | RTS low = 16 mA (maximum) |
| Active | memory test (worst case) = 30 mA (typical) |
RS-232 Input Levels |
|
| Low Threshold | 0.8 V (maximum) |
| High Threshold | 2.0 V (minimum) |
| Maximum Input Limit | 30 V |
| Minimum Input Resistance | 3500 Ω |
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
| 製品 | 互換性 | 注意 |
|---|---|---|
| 21X (リタイア) | ||
| CR10 (リタイア) | ||
| CR1000 (リタイア) | ||
| CR10X (リタイア) | ||
| CR200X (リタイア) | ||
| CR206X (リタイア) | ||
| CR211X (リタイア) | ||
| CR216X (リタイア) | ||
| CR23X (リタイア) | ||
| CR295X (リタイア) | ||
| CR3000 (リタイア) | ||
| CR500 (リタイア) | ||
| CR5000 (リタイア) | ||
| CR510 (リタイア) | ||
| CR800 (リタイア) | ||
| CR850 (リタイア) | ||
| CR9000 (リタイア) | ||
| CR9000X (リタイア) |
| 製品 | 互換性 | 注意 |
|---|---|---|
| DSP4 (リタイア) |
The MCR1 is only compatible with mixed-array data loggers (see below). Data loggers that store data in a table-based format are not compatible. Older data loggers may require a PROM upgrade.
The MCR1 uses one JEIDA 4, PCMCIA card; proper MCR1 operation is guaranteed only with cards tested by Campbell Scientific.
We've updated our privacy policy. 詳細はこちら
Update your cookie preferences. クッキーの設定を更新する