Your data logger can measure more switch closures or voltage pulses with an SDM-SW8A. Sensors that output a switch closure or voltage pulse signal include tipping bucket rain gages, flow meters, and anemometers.
続きを読む 
				 
							 
							The SDM-SW8A provides eight channels for connecting the sensors. Each channel is individually configured for single-pole double-throw (SPDT), single-pole single-throw (SPST), or voltage pulse measurements. Output options include counts, duty cycle, and state.
The data logger enables individual modules through an addressing scheme; multiple SDMs (in any combination) can be connected to one data logger. We recommend a maximum of four SDM-SW8As be connected to a single data logger. After a module is enabled, it operates independently of the data logger until additional commands are received or results are transmitted.
| Function | Increases the number of switch closures or voltage pulses a data logger can measure. | 
| Number of Channels | 8 | 
| Measurement Types | Switch closure (SPDT, SPST), dc voltage pulse | 
| Input Voltage Threshold | From below 0.9 to above 4.0 Vdc (±20 Vdc maximum) | 
| Maximum Input Frequency | 100 Hz (50% duty cycle) | 
| Minimum Input Pulse Width | 5 ms high, 5 ms low | 
| Maximum Bounce Time | 3 ms open without counting | 
| Output Options | State, duty cycle, counts | 
| Maximum Count/Port | 65535 | 
| Internal Sampling Frequency | 500 Hz | 
| Watchdog Reset | Yes | 
| Operating Temperature | -25° to +55°C | 
| Operating Voltage | 9.6 to 16 V | 
| Typical Current Drain | 
 | 
| Relative Humidity | 0 to 90% RH (non-condensing) | 
| Maximum Cable Length | 6 m (20 ft) total to all SDM devices Consult Campbell Scientific if longer lengths are necessary. | 
| Dimensions | 15.7 x 6.9 x 2.3 cm (6.2 x 2.7 x 0.9 in.) | 
| Weight | 0.23 kg (0.5 lb) | 
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
| 製品 | 互換性 | 注意 | 
|---|---|---|
| 21X (リタイア) | ||
| CR10 (リタイア) | ||
| CR1000 (リタイア) | ||
| CR1000X (リタイア) | ||
| CR10X (リタイア) | ||
| CR200X (リタイア) | ||
| CR206X (リタイア) | ||
| CR211X (リタイア) | ||
| CR216X (リタイア) | ||
| CR23X (リタイア) | ||
| CR295X (リタイア) | ||
| CR300 (リタイア) | ||
| CR3000 (リタイア) | For the CR3000, SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
| CR310 | ||
| CR500 (リタイア) | ||
| CR5000 (リタイア) | For the CR5000, SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
| CR510 (リタイア) | ||
| CR6 | ||
| CR800 (リタイア) | ||
| CR850 (リタイア) | ||
| CR9000 (リタイア) | ||
| CR9000X (リタイア) | 
| 製品 | 互換性 | 注意 | 
|---|---|---|
| Granite 10 | ||
| Granite 6 (リタイア) | ||
| Granite 9 | 
In the CRBasic data loggers, the SDM-SW8A operation is controlled by the SDMSW8A instruction. Instruction 102 controls the SDM-SW8A operation for Edlog data loggers that were shipped after October 1988 (consult Campbell Scientific for equipment shipped prior to this date).
Due to the 3 mA continuous and 6 mA active current drain, an auxiliary 12 Vdc power supply is recommended for powering the SDM-SW8A in remote, long-term applications.
For some applications, it may be convenient to use the data logger power supply. You can do this where ac power is available, or where a solar panel can be used for recharging the data logger's sealed rechargeable battery.
The SDM-SW8A requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the SDM-SW8A to the backplate of our enclosures.